|
|
|
 |
Macrogen Inc. offers DNA sequencing using state-of-the-art
robotics and instrumentation to generate high quality sequence data
at affordable prices. We have successfully sequenced countless samples
of PCR products, plasmids, and BACs from clients all over the world,
and our DNA sequencing services are highly rated for their turnaround
time, quality of results, and competitive prices.
Macrogen Standard Sequencing Brochure Download
|
 |
It is the most typical single primer extension
service. Plasmid or PCR product template is read with your designated primer.
|
Standard-seq single |
| It is highly automated to allow rapid processing
of plasmids and PCR products. Samples can be sent as clones, un-purified
PCR products and purified DNA. |
|
For the customers with large number of samples processed
in 96-well plates, this will be a better option. "Plate Sequencing" refers
to the orders charged per one entire 96-well plate. Samples can be sent
as clones, un-purified PCR products and purified DNA.
* Note:
- The well to well variation of the concentration of your
samples is very important to get better results,
please keep it as constant as possible.
- Free retrial is not available for this service. Any retrial request will be
regarded as a new order of regular reaction.
|
1 primer / 1plate |
" 1 Primer / 1 Plate" refers to the orders
charged per plate.
To use this order, your samples should meet all of the following
criteria.
- Samples are sent to Macrogen pre-arranged in 96-well plate.
- One single primer should be applied to the whole plate,
so that we Macrogen can simply put the primers to the
corresponding sample
plate.
- No sample name is required, but plate name is enough for
this service.
We will provide the results as the following file name.
[Plate_name]-[Well_position]_[Primer_name].ab1
ex)
HCVNS5B-H05_SP6.ab1
BRCA2-D24_T7.ab1 |
|
2 primer / 1plate |
"2 Primer / 1 Plate" refers to the orders
charged per plate.
To use this order, your samples should meet all of the following criteria.
- Samples are sent to Macrogen pre-arranged in 96-well plates.
- Only two custom primers (or two universal primers) in tubes could be
acceptable for applying this
Plate sequencing.
- Sample and primer name is shown in the results.
[Sample_name]-[Primer_name].ab1
ex)
HCVNS5B_SP6.ab1
BRCA2-A02_T7.ab1 |
*Note : For three more primers, your order will be regarded as Single sequencing
reactions
|
multi
primers / 1plate |
"Multiple Primers / 1 Plate"can be applicable
in case you send primers in the plate which has same well
position information with the sample plate regardless of primer's quantity.
To
use this order, your samples should meet all of the following
criteria.
- Samples are sent to Macrogen pre-arranged in 96-well plate.
- Primers are sent to Macrogen pre-arranged in 96-well plate
and have same well position information with
the sample plate. (e.g.
The primer
which is supposed to run with the sample in well A01
should be placed in well A01.)
*Note : Each paired primer should be filled in the 96-well plate
which has same well position with the paired sample plate. |
|